Bante Multiparameter Water Quality Meter

BANTE90 series water quality meters are designed for high performance and easy operation. With 10 models to choose from per your requirements. The meters are capable of measuring up to 8 water quality parameters, including pH, ORP, Ion, DO, Conductivity, TDS, Salinity, Resistivity and temperature.

 

 

 

Multiparameter

  Model Parameter Range and Accuracy Description  
   
  BANTE900 pHORPIon Conductivity TDS Salinity Resistivity DO oC/oF   pH Range: -2.000 to 16.000pH pH Accuracy: ±0.002pHORP Range: 0 to ±1999.0mVORP Accuracy: ±0.2mVIon Concentration: 0 to 19999ppm Accuracy: ±0.5% (monovalent); ±1% (divalent) Conductivity Range: 0 to 200mS/cm Conductivity Accuracy: ±0.5% F.S TDS Range: 0 to Max.200ppt TDS Accuracy: ±1% F.S Salinity Range: 0 to 50ppt Salinity Accuracy: ±1% F.S Resistivity Range: 0 to 100MΩ/cmResistivity Accuracy: ±1% F.S Dissolved Oxygen: 0.0 to 20.0mg/LAccuracy: ±0.3mg/L% Saturation of Oxygen: 0~200%Accuracy: ±5.00%Temp Range: 0~100oC Temp Accuracy: ±1oC       Multipoint Push-Button CalibrationAutomatic Temperature Compensation Calibration Solution Recognition USA and NIST pH buffer standards Auto-Ranging Capability Adjustable Temperature Coefficient Adjustable TDS Factor Salinity CompensationBarometric Pressure Compensation99 Data Sets USB Communication interface  
  BANTE901 pHORPConductivity TDS Salinity Resistivity oC/oF   pH Range: -2.000 to 16.000pH pH Accuracy: ±0.002pHORP Range: 0 to ±1999.0mVORP Accuracy: ±0.2mVConductivity Range: 0 to 200mS/cm Conductivity Accuracy: ±0.5% F.S TDS Range: 0 to Max.200ppt TDS Accuracy: ±1% F.S Salinity Range: 0 to 50ppt Salinity Accuracy: ±1% F.S Resistivity Range: 0 to 100MΩ/cmResistivity Accuracy: ±1% F.S Temp Range: 0~100oC Temp Accuracy: ±1oC       Multipoint Push-Button CalibrationAutomatic Temperature Compensation Calibration Solution Recognition USA and NIST pH buffer standards Auto-Ranging Capability Adjustable Temperature Coefficient Adjustable TDS Factor 99 Data Sets USB Communication interface  
  BANTE902 pHORP DO oC/oF   pH Range: -2.000 to 16.000pH pH Accuracy: ±0.002pHORP Range: 0 to ±1999.0mVORP Accuracy: ±0.2mVDissolved Oxygen: 0.0 to 20.0mg/LAccuracy: ±0.3mg/L% Saturation of Oxygen: 0~200%Accuracy: ±5.00%Temp Range: 0~100oC Temp Accuracy: ±1oC       Multipoint Push-Button CalibrationAutomatic Temperature Compensation Calibration Solution Recognition USA and NIST pH buffer standards Salinity CompensationBarometric Pressure Compensation99 Data Sets USB Communication interface
  BANTE903 Conductivity TDS Salinity Resistivity DO oC/oF   Conductivity Range: 0 to 200mS/cm Conductivity Accuracy: ±0.5% F.S TDS Range: 0 to Max.200ppt TDS Accuracy: ±1% F.S Salinity Range: 0 to 50ppt Salinity Accuracy: ±1% F.S Resistivity Range: 0 to 100MΩ/cmResistivity Accuracy: ±1% F.S Dissolved Oxygen: 0.0 to 20.0mg/LAccuracy: ±0.3mg/L% Saturation of Oxygen: 0~200%Accuracy: ±5.00%Temp Range: 0~100oC Temp Accuracy: ±1oC     Multipoint Push-Button CalibrationAutomatic Temperature Compensation Calibration Solution Recognition Auto-Ranging Capability Adjustable Temperature Coefficient Adjustable TDS Factor Salinity CompensationBarometric Pressure Compensation99 Data Sets USB Communication interface