PolyScience Accessories

510-451

Protective Heater Shield For use with PolyScience Immersion Circulators. Protective Shield prevents samples from touching the Thermal Circulator’s heater element or pump

040800 Flask holder, 25ml

040802 Flask holder, 50ml

040804 Flask holder, 125ml

040806 Flask holder, 250ml

040808 Flask holder, 500ml

040810 Flask holder, 1000ml

050300 Cooling coils for immersion circulators Model 71 and 7306

060101 Remote probe - 10 ft. (3m) Custom lengths available on special order. For circulators with programmable controller. Permits point of control to be switched from inside programmable circulator bath to a remote location such as an open tank. Compensates for heat losses through tubing between the circulator and the control point. Platinum RTD sensor with stainless steel sheath 5/32 dia. x 6 in. long (.4 dia. x 15.2cm). One inch (2.54cm) rubber coupling connects sheath to flexible cable. Probe cable ends in DB9 female plug

060105 Remote probe - 25 ft. (7.6m) Custom lengths available on special order. For circulators with programmable controller. Permits point of control to be switched from inside programmable circulator bath to a remote location such as an open tank. Compensates for heat losses through tubing between the circulator and the control point. Platinum RTD sensor with stainless steel sheath 5/32 dia. x 6 in. long (.4 dia. x 15.2cm). One inch (2.54cm) rubber coupling connects sheath to flexible cable. Probe cable ends in DB9 female plug

060110 Remote probe - 50ft. (15.25m) Custom lengths available on special order. For circulators with programmable controller. Permits point of control to be switched from inside programmable circulator bath to a remote location such as an open tank. Compensates for heat losses through tubing between the circulator and the control point. Platinum RTD sensor with stainless steel sheath 5/32 dia. x 6 in. long (.4 dia. x 15.2cm). One inch (2.54cm) rubber coupling connects sheath to flexible cable. Probe cable ends in DB9 female plug

060300 Cooling coils for heating circulators

060301 Hollow Plastic Floating Balls - 3/4 in. (20mm) diameter, Pack of Create a blanket of insulation in any open bath, reducing heat loss 75% and evaporation by 87%. Reduce fumes and splashing hazards. Usable to temperatures to 110°C and in most bath fluids. Made of polypropylene.

060302 Chiller External Pressure Reducer For chillers equipped with high pressure, positive displacement pumps capable of producing 20-100 psi. (Models ending in "P"). Reduces the output of the chiller to an adjustable range of 10-45 psi.

060304 Tubing clamp for 3mm to 13mm tubing

060305 Brass reducing adapters 8mm I.D. (set of 2)

060307 Buna N tubing 5/16 in. (8mm) I.D. per yard (.9m)

060308 Buna N tubing 1/2 in. (13mm) I.D. per yard (.9m)

060309 Insulation for 5/16 in. (8mm) tubing per yard (.9m)

060310 3 ft. (.93m) flexible Teflon® lined, stainless steel overbraid tubing 1/4 in. NPT quick connects at both ends. Maximum temperature use 300°C

060311 Insulation for 1/2 in. (13mm) tubing per yard (.9m)

060312 Low Temperature Insulated Tubing - 6 ft. (1.9m) Minimizes temperature loss from a circulator to external device. 6 ft. (1.9m) of 1/2 in. (1.27cm) I.D. Buna N tubing with foam insulation.

060314 Tube, hose barb 1/4 MPT to 13mm brass (set of 2)

060326 Dow Corning 510 - 1gal (3.785L) Temperature range: 50° to 150°C (122° to 302°F)
Freezing point: -70°C (-94°F)
Viscosity: @25°C 50 cSt

Due to high viscosity, Silicone fluids 510, 550 and 710 are not recommended for use below 90°C.
Dow Corning fluids are produced by and registered TMs of Dow Corning Corporation.


060327 Dow Corning 550 - 1 gal (3.785L) Temperature range: 100° to 200°C (212° to 392°F)
Freezing point: -50°C (-58°F)
Viscosity: @25°C 125 cSt

Due to high viscosity, Silicone fluids 510, 550 and 710 are not recommended for use below 90°C.
Dow Corning fluids are produced by and registered TMs of Dow Corning Corporation.


060328 Dow Corning 710 - 1 gal (3.785L) Temperature range: 150° to 250°C (302° to 482°F)
Freezing point: -22°C (-7.6°F)
Viscosity: @25°C 500 cSt

Due to high viscosity, Silicone fluids 510, 550 and 710 are not recommended for use below 90°C.
Dow Corning fluids are produced by and registered TMs of Dow Corning Corporation.


060330 Dynalene HC 50 - 1gal (3.785L) Temperature range: -50° to 60°C (-58° to 140°F)
Freezing point: -62°C (-76°F)
Viscocity: @0°C 3.6 cSt, @-40°C 15.1 cSt

060340 Ethylene Glycol 1 U.S. Gallon (3.785L)

062120 Digital to analog adapter For circulators with programmable controller when direct digital control is not required. Connects to the RS-232 port and provides 10mv/degree analog signal for external monitoring or control.

099590 Thermometer, glass, -20ºC to 150ºC

4-300040 Lab Algacide - 8oz A general purpose lab algicide that helps keep water baths clean, odor free, and resistant to black algae. Stainless steel compatible. Use 20 drops/gal. to prevent algae growth. 8 oz.dispenser bottle treats approximately 200 gallons.

4-300050 Concentrated bath cleaner (8oz. bottle) A concentrated liquid for cleaning, removing rust & mineral deposits from stainless steel and plastic baths. For best results, use at elevated temperatures. Helps remove existing algae prior to treatment with Lab Algicide. 1 oz. treats approximately 2 gal.

040904 18L Polycarbonate Tank Maximum Temperature 210°F / 99°C, Overall Dimensions(L x W x D) 18 x 12 x 9 in (45.7 x 30.5 x 22.9 cm)

060974 Polycarbonate Lid 12" X 18" with cutout These custom fabricated lids are designed to fit on commonly used Cambro brand food storage tanks; when used in conjunction with a 7306 Immersion Circulator with a protective shield attached.

510-117 Shaker attachment lid, 20 & 28 liter

510-149 Chiller adapter kit Contains Two (2) Pairs of nylon 90º elbow fittings: 1/2" male NPT x 1/2" hose barb, 1/2" male NPT x 5/8" hose barb .